● Single axis tilt measurement
● Resolution: 0.01°
● Power supply:12-36V
● Volume: L90*W40.5*H26( mm)
● Accuracy: 0.1°
● Range: ±180°
● Output: 0-5V/0-10V for optional
● IP67 protection level
Electrical index
Parameter | Condition | Minimum | Typical value | Maximum | |
Power voltage(V) | 12 | 36 | |||
Operating current(mA) | No load | 20 | 30 | 40 | |
Operating temperature(℃) | -40 | 85 | |||
Storage temperature(℃) | -55 | 100 |
Performance Index
Measurement Range (°) | Condition |
|
Measurement axis |
|
|
Accuracy (°) | Room temperature |
|
Resolution (°) | Completely still |
|
Start-up time |
|
|
Output frequency (Hz) | 100 | |
Zero Point Voltage Output(V) | 2.5 (0 to 5 output); 5 (0 to 10 output) | |
Full-scale output voltage range (V) | 0~5 ;0~10 | |
Mean time between failures MTBF | ≥90000 h/times | |
Electromagnetic | According to GBT17626 | |
Insulation resistance | ≥100 MΩ | |
Impact resistance | 2000g, 0.5ms, 3 times/axis | |
Weight (g) | 210(without outer packaging) |