● Single axis tilt measurement
● Resolution: 0.01°
● Power supply: 9-36V
● Volume: L55*W37*H24(mm)
● Highest accuracy:0.1°
● Range:±180°
● Output:CAN
● IP67 protection level
Electrical index
Parameter | Condition | Minimum | Typical value | Maximum | |||
Power voltage(V) | 9 | 12 | 36 | ||||
Operating current(mA) | No load | 20 | 30 | 40 | |||
Operating temperature (℃) | -40 | 85 | |||||
Storage temperature (℃) | -55 | 100 |
Performance Index
Measurement Range (°)
| Condition | ±180 | |
Measurement axis | X | ||
Accuracy(°) | Room temperature | 0.1 | |
Resolution(°) | Completely still | 0.01 | |
Start-up time | <3s | ||
Output frequency (Hz) | 5-100Hz adjustable | Up to 100 | |
Mean time between failures MTBF | ≥90000 h/times | ||
Electromagnetic compatibility | According to GBT17626 | ||
Insulation resistance | ≥100 MΩ | ||
Impact resistance | 2000g,0.5ms,3times/ axis | ||
Weight (g) | 210( Without outer packaging ) |