● Range: ±30°
● Wide voltage input:12-36V
● Single axis inclination measurement
● Output: 0-5V, 0-10V optional
● Highest accuracy: 0.003°
● Output frequency 100Hz
● High resolution: 0.0007°
● Wide temperature work:-40℃~+85℃
Electrical Index
Parameter | Condition | Minimum | Typical value | Maximum | |||
Voltage (V) | 12 | 36 | |||||
Current (mA) | No load | 20 | 50 | 60 | |||
Output (kΩ) | Resistive | 10 | |||||
Output (nF) | Capacitive | 20 | |||||
Operating temperature(℃) | -40 | 85 | |||||
Storage temperature(℃) | -55 | 100 |
Performance Index
Measurement range(°)
| Condition | ±15 | ±30 | |
Measurement axis | X | X | ||
Accuracy(°) | Highest | 0.003 | 0.005 | |
Resolution(°) | Completely still | 0.0007 | 0.0007 | |
Zero bias(°/℃) | -40~85℃ | ±0.0007 | ±0.0007 | |
Start-up time | 0.05 | 0.05 | ||
Output frequency (Hz) | 100 | |||
Full-scale output voltage range (V) | 0~5V、0~10V(optional) | |||
Mean time between failures MTBF | ≥90000 hours | |||
Electromagnetic compatibility | According to GBT17626 | |||
Insulation resistance | ≥100 MΩ | |||
Impact resistance | 2000g,0.5ms,3times/axis |