● Range: ±30°
● Wide voltage input:9-36V
● Dual axis inclination measurement
● Output: CAN
● Highest accuracy: 0.003°
● IP protection level:IP67
● High resolution: 0.0007°
● Wide temperature work:-40℃~+85℃
Electrical Index
Parameter | Condition | Minimum | Typical value | Maximum | |||
Voltage (V) | 9 | 12 | 36 | ||||
Current (mA) | No load | 20 | 30 | 40 | |||
Operating temperature(℃) | -40 | 85 | |||||
Storage temperature(℃) | -55 | 100 |
Performance Index
Measurement range (°)
| Condition | ±15 | ±30 | ||
Measurement axis | X-Y | X-Y | |||
Accuracy(°) | Highest | 0.003 | 0.005 | ||
Resolution(°) | Completely still | 0.0007 | 0.0007 | ||
Zero bias (°/℃) | -40~85℃ | ±0.0007 | ±0.0007 | ||
Start-up time | <3s | <3s | |||
Output frequency (Hz) | 5-100Hz adjustable | Up to 100 | Up to 100 | ||
Full-scale output voltage range | 0~5V, 0~10V (optional) | ||||
Mean time between failures MTBF | ≥90000 hours | ||||
Electromagnetic compatibility | According to GBT17626 | ||||
Insulation resistance | ≥100 MΩ | ||||
Impact resistance | 2000g,0.5ms,3times/axis |