●Dual axis tilt measurement
●High accuracy:0.001°
●Cross axis error: 0.001°
●High level EMC Protection
●Temperature drift: 0.0003°/℃
●Wide voltage input 9-36V DC
●Output frequency 5~100Hz adjustable
●OEM customization accepted
Measurement Range (°) | Condition | ±5 | ±15 | ||||
Measurement axis | Mutually perpendicular | X-Y | X-Y | ||||
Accuracy (°) | Room temperature | 0.001 | 0.003 | ||||
Cross axis error (°) | -40~85℃ | 0.001 | 0.003 | ||||
Resolution (°) | Completely still | 0.0001 | |||||
Zero bias (°/℃) | -40~85℃ | ±0.0003 | |||||
Start-up time | <3s | ||||||
Output frequency (Hz) | 5-100Hz adjustable | Up to 100 | |||||
Baud rate | Adjustable | 2400~115200 | |||||
Mean time between failures MTBF | ≥90000 h/time | ||||||
Electromagnetic compatibility | According to GBT17626 | ||||||
Insulation resistance | ≥100MΩ | ||||||
Weight (g) | 320 (metal plug) / 350 (airline plug) | ||||||
Electrostatic Discharge (ESD) | IEC 61000-4-2 Class IV | Contact discharge 8KV, air discharge 15KV | |||||
Fast transient burst immunity | IEC 61000-4-4 Class IV | Repetition frequency 5kHz, positive and negative power supply 4KV, signal line 2KV | |||||

+86 189 2129 2620